Verantos presents abstract on largest ever moderate-to-severe asthma dataset at 42nd ISPE
Verantos, Optum Life Sciences, and Amgen used artificial intelligence to build a high-validity Pragmatic Registry of 349,600 US patients with moderate-to-severe asthma. Curated variables reached 91% accuracy against a clinician-annotated reference standard, and every optimized variable exceeded 80% accuracy. The work is presented at ISPE 2026, the annual meeting of the International Society for Pharmacoepidemiology.
Why data reliability matters in asthma research
US Food and Drug Administration guidance on real-world data from electronic health records and claims emphasizes that data must be both relevant and reliable to be fit for use in regulatory decisions. Observational asthma research often falls short on relevance because claims and structured records lack specific detail on disease severity and test results. This work builds on methods from the FDA-funded TRUST study to address that gap at scale.
How the data were curated
The registry draws on US health systems and Optum Market Clarity data, including claims and structured and unstructured electronic health record data for every patient. Patients aged 12 and older entered the registry between 2015 and 2024 through a clinician diagnosis of moderate-to-severe asthma or a medication-based algorithm.
- Artificial intelligence processed clinical narratives at scale to extract variables found only in unstructured text, such as pulmonary function test values with the test, date, result, and unit.
- Two clinician annotators labeled each concept to create a reference standard for model validation, with an average Cohen’s kappa above 0.7 required.
- Each concept was optimized for both the disease and the data source.
- Curated data were linked with structured records, claims, and mortality data while remaining certified de-identified.
Key findings
From more than 200 million patients across the catchment areas, the registry identified 349,600 patients with moderate-to-severe asthma and a median follow-up of 83 months.
- Data reliability reached 91% accuracy (90% recall and 92% precision), 72% completeness, and 64% traceability, measured with peer-reviewed methods.
- Pulmonary function test results increased 88-fold, from 9,840 to 866,456.
- Patients identified as having severe asthma more than doubled, from 5.8% to 13.9%.
- Identification of patients with cough, dyspnea, and wheezing increased 59- to 77-fold.
Variables traditional data miss
Forced expiratory volume in one second (FEV1), forced vital capacity (FVC), and the FEV1/FVC ratio may be coded as procedures, but their results usually appear only in clinical notes. Symptoms such as chest tightness, cough, dyspnea, and wheezing are often coded vaguely or not at all. The registry captures these concepts directly from the clinical record.
What it means
Combining curated variables with structured records and claims produced a dataset that is both rich and reliable. The results show that this level of data quality is achievable at scale and establish a framework for applying the same approach across other therapeutic areas.